Telescope
|
| Length
|
171mm
|
| Objective
aperture |
45mm
(1.8 in.) (EDM: 48mm (1.9 in.) |
| Magnification
|
30x
|
| Resolving
power |
2.5"
or better |
| Field
of view |
1°
30' (26m/1,000m) |
| Minimum
focus |
1.3m(4.3
ft.) |
| Reticle
illumination |
5
brightness levels |
|
Angle
Measurement
|
| Type
H&V |
Photoelectric
absolute encoder scanning. Both circles adopt diametrical detection |
| Display
resolutions (selectable) |
0.5"/1",0.1/02.mgon,0.002/0.005mil |
| Accuracy
|
1"/0.3mgon/0.005mil |
| Automatic
dual-axis compensator |
Dual-axis
liquid tilt sensor. Working range: ±3' (±55mgon) |
| Display
mode H&V |
Clockwise/counterclockwise
selectable
Zenith 0°/horizontal 0° selectable |
|
Distance
Measurement
|
| Light
source |
Modulated
Near-infrared light-emitting diode |
| Measuring
range |
2m(6.6ft)
to 100m(328ft) (RS90 reflective sheets target)50m(164ft) to 1000m(3,280ft)(using
CPS12 high-precision reflective prism) |
| Minimum
resolution - Fine measurement |
0.0001m/0.001m(0.001ft/0.01ft)selectable
|
| Minimum
resolution - High-speed measurement |
0.001m(0.01ft)
|
| Tracking
|
0.01m(0.1ft)
|
| Accuracy
|
±
(0.8mm + 1ppm x D)mm, reflective sheet target; ±(2.0+2ppm x D)mm
(using CPS12 high precision reflective prism. |
| Measuring
time - Fine measurement |
Every
4.7s (initial meas. 6.5s) |
| Measuring
time - High-speed measurement |
Every
3.3s (initial meas. 5.0s) |
| Display
range |
0.0001
to 1599.9999m(5249.3332ft) |
| Atmospheric
correction |
Selectable
(1) Direct key-in of temperature and pressure (hPa/mmHg)(2) Direct key-in
of temperature, pressure (hPa/mmHg) and humidity (3) Direct key-in of
ppm (4) No correction |
|
General
|
| Display
|
Alphanumerics,
graphics Dot matrix LCD on each face 20 chars. x 8 lines, 120 x 64 dots,
Non-reflective glass, backlight |
| Keyboard
|
28
Latex keys on each face (numeric, cursor, edit, power, softkey function,
illumination) |
| Sensitivity
of levels - Plate level |
20"/2mm
|
| Sensitivity
of levels - Circular level |
10'/2mm
|
| Optical
plummet |
Image:
erect. Magnification: 7x. Minimum focus: 0.5m |
| Standing
(vertical) axis |
Independent
double-axis |
| Battery
level display |
4-stage
power codes, with message display |
| Automatic
power cut-off |
30
minutes after last operation, ON/OFF selectable |
| Data
storage Internal memory capacity |
448KB
(Approx. 3,000 points) |
| Interface
|
Asychronous
serial, RS-232C compatible, Centronics compatible |
| Operating
temperature |
-10°C
to +40°C (14°F to 104°F) |
| Water
resistance |
IPX2
(Based on IEC 529/1989) |
| Size
with handle and BDC35 battery |
177(W)
x 165(D) x 371(H) mm (7.0(H) x 6.5(D) x 14.6(H) in.) |
| Instrument
height (horizontal axis height) |
236mm
(9.3 in.) from tribrach bottom, 193mm (7.6 in.) from tribrach dish |
| Weight
|
6.1kg
(13.4 lb.)(including handle and battery) |
|
Power
supplies
|
| Voltage
|
7.2V
DC |
| BDC46A
detachable battery |
Li-Ion
rechargeable battery, 2 BDC46A are included as standard accessories |
| Continuous
use per battery |
About
6 hours single measurement every 30 seconds at 25°C (77°F),
laser-pointer and target illumination off) |
| Recharging
time per battery |
Less
than 2 hours with CDC61/62/64 |
| BDC12
external Ni-Cd battery (optional) |
Continuous
use about 22.5 hours single measurement every 30 seconds at 25°C
(77°F) |