Laser & Survey Solutions
Laser & Survey Solutions

Advancing measurement - with the complete wireless freedom of a FaroArm

FARO‘s portable measuring arms make measuring complex objects easy. This includes alignment, calibration, inspection, reverse engineering and as-built documentation with an accuracy up to 16 microns. Save energy and extend component life with the new auto sleep mode, and enjoy complete wireless freedom thanks to Bluetooth®

FaroArm Quantum :

Quality in production begins with accuracy in product measurements. To achieve the highest levels of accuracy, manufacturers were forced to measure their parts in a controlled environment using large, expensive coordinate measuring machines (CMM).

The FaroArm® Quantum now has the power to inspect and perform CAD-to-part analysis in any environment with very high accuracy (28 microns volumetric accuracy for an 8ft./2.4m arm).

It is the ideal tool for completing surface measurements and dimensional calculations to the highest degree of accuracy and performs CAD analysis, inspections and alignments with ease and precision.

FAROARM PERFORMANCE SPECIFICATIONS: Quantum
 
1.8m (6ft.)
2.4m (8ft.)
3.0m (10ft.)
3.7m (12ft.)
 
6 Axis
7 Axis
6 Axis
7 Axis
6 Axis
7 Axis
6 Axis
7 Axis
Single Point Articulation Performance Test (Max-Min)/2¹:
±.016mm (±.0006in.)
±.019mm (±.0007in.)
±.018mm (±.0007in.)
±.020mm (±.0008in.)
±.032mm (±.0013in.)
±.039mm
(±.0015in.)
±.043mm
(±.0017in.)
±.051mm
(±.0020in.)
Volumetric Maximum Deviation²:
.023mm (.0009in.)
.027mm (.0011in.)
.025mm (.0010in.)
.028mm
( .0011in.)
.046mm (.0018in.)
.055mm
(.0022in.)
.060mm
(.0024in.)
.072mm
(.0028in.)
Weight:
9.30kg (20.5lbs.)
9.50kg
(21.0lbs.)
9.50kg (21.0lbs.)
9.75kg (21.5lbs.)
9.75kg (21.5lbs.)
9.98kg
(22lbs.)
9.98kg
(22lbs.)
10.21kg
(22.5lbs.)

FaroArm Test Methods - (Test methods are a subset of those given in the B89.4.22 standard.)

¹ Single Point Articulation Performance Test (Max-Min)/2 (SPAT):
The probe of the FaroArm is placed within a conical socket, and individual points are measured from multiple approach directions. Each individual point measurement is analyzed as a range of deviations in X, Y, Z. This test is a method for determining articulating measurement machine repeatability.

² Volumetric Maximum Deviation
Determined by using traceable length artifacts, which are measured at various locations and orientations throughout the working volume of the FaroArm. This test is a method for determining articulating measurement machine accuracy.

 

[BACK]